Coordinate antiscalant, pH or dechlorination duties with the RO projection.
Review industrial RO membranes →YiFu Trading
A moderate-flow Tekna AKS size with a higher published pressure envelope. Published family size: 7–18 l/h, with pressure up to 16 bar.
Model selection
SEKO Tekna AKS800 may be considered when the calculated dosing flow and actual discharge pressure fit the manufacturer-approved performance curve. The published 7–18 l/h and up-to-16 bar envelope is a size range, not confirmation that every flow is available at every pressure.
It may be reviewed for chemical injection into moderate- or higher-pressure water-treatment lines, including defined RO conditioning duties, when the required operating point is verified against the approved curve.
YiFu Trading supplies dosing pumps as supporting equipment for membrane and water-treatment projects. YiFu does not claim to be an authorized SEKO distributor, and the exact revision, liquid end, connections, accessories and delivery scope must be confirmed before quotation.

Published hydraulic envelope
SEKO's Tekna series brochure is the source for the model-size range below. Final selection requires the current technical data sheet and the applicable performance curve.
| Model | SEKO Tekna AKS800 |
|---|---|
| Published flow range | 7–18 l/h |
| Published pressure range | Up to 16 bar |
| Dosing mode | Constant dosing with an analog interface for the AKS family |
| Configuration status | Liquid-end materials, seals, voltage, connections, stroke data and accessories require order-specific confirmation |
Engineering checks
Do not assume AKS800 delivers 18 l/h at 16 bar. Reject the selection if the verified curve, liquid-end materials, control method or installation arrangement does not match the project duty.
A proportional control signal, degassing head, hazardous-area approval, redundancy requirement or unusually viscous or gas-forming chemical may point to another pump configuration even when nominal flow and pressure appear acceptable.
Membrane-system integration
The pump is supporting equipment. The membrane process and chemical program define where and why dosing is required.
Coordinate antiscalant, pH or dechlorination duties with the RO projection.
Review industrial RO membranes →Check intake pretreatment, chemical compatibility and the verified injection pressure.
Review seawater RO membranes →Define particulate, scaling, oxidant and biological controls as one treatment train.
Review RO pretreatment →Base reagent dosing on representative water data and the selected process step.
Review industrial wastewater →Connect chemical conditioning to the required reuse quality and downstream equipment.
Review water reuse →Compare the published hydraulic envelopes of AKS603, AKS800 and AKS803.
Compare all three models →Request a configuration review
Provide the destination country plus the chemical and concentration, required flow, required discharge pressure, dosing application and quantity. Include the control method and injection-point conditions in the application description.
For manufacturer information, consult the official SEKO Tekna AKS page and the current technical data sheet.